Tip/tilt control strategies of E-ELT

Oct 24, 2018, 9:30 AM
30m
Amphithéâtre Turing (Paris)

Amphithéâtre Turing

Paris

Université Paris Diderot Bâtiment Sophie Germain, niveau -1 8 place Aurélie Nemours - 75013 Paris

Speaker

Dr Babak Sedghi (ESO)

Summary

The image motion (tip/tilt) of the telescope is dominated by two types of perturbations: a) atmospheric b)
wind load. The wind load effect on E-ELT can be an order of magnitude higher than the atmospheric effect.
Part of the image motion due to the wind load on the telescope structure is corrected by the main axis control
system (mainly large amplitude, low frequency errors). The residual tip/tilt is reduced by M5 and M4 mirror
units. M5 with its large stroke and relative low bandwidth (higher than main axes) corrects for large amplitude
and low frequency part of the image motion and M4 unit takes the higher frequency parts with smaller stroke
availability. In this talk control strategies, in particular a two-stage control strategy for decoupling M4-M5, are presented and the results are discussed.